Pumping stations with belt drive SN-R1-05

Pumping stations SN-R1-05 are intended to pump various liquids:

  • abrasive hydraulic fluids (clay and gravel mortars, mixtures of water and sand, ore, etc.);
  • flushing liquid used in the course of well drilling;
  • household and industrial waste waters;
  • for pumping drilling waste (drill cuttings, waste drilling fluid), oil-contaminated soil and process effluents from oil producing and oil refineries.

Pumping station SN-60R1-05

Parameter name SN-60.16,6.1,9R1-05.100.15.22
Rated flow, m3/h (lps) at head, wcm. (bar) 60 (16,7) / 16,6 (1,66)
Max head, wcm (bar) 18 (1,8)
Base pump model NC-100R1
Pressure flange DN, mm 100 (4")
Inlet flange DN, mm 125 (5")
Dimentions, LxBxH, mm 1150х510х1150
Station weight, kg, ±5% 620
Equipment placement category NF
Ambient temperature -45˚С ... +40˚С
Controlled fluid temperature 0˚С ... +80˚С
Pumped fluid properties:
hydraulic fluid density, kg/m3 up to 1900
Temperature, °С +5 ... +55
solid particle content up to 60%
solid particle maximal size, mm at most 13
Electric motor:
Power, kW 22
Rate speed, rpm 1500
Rated current at 380 W, A 42
IP Code IP55

* L – length, W – width, H – height

Operating specifications of pumping stations based on pumps of NC-100R1 series

Pumping station SN-60R1-05

Parameter name SN-60.40.1,5R1-05.76.15.30.В
Rated flow, m3/h (lps) at head, wcm. (bar) 60 (16,7) / 40 (4,0)
Max head, wcm (bar) 42 (4,2)
Base pump model NC-76R1
Pressure flange DN, mm 76 (3")
Inlet flange DN, mm 100 (4")
Dimentions, LxBxH, mm 1050х550х1200
Station weight, kg, ±5% 520
Equipment placement category NF
Ambient temperature -45˚С ... +40˚С
Controlled fluid temperature 0˚С ... +80˚С
Pumped fluid properties:
hydraulic fluid density, kg/m3 up to 1500
Temperature, °С +5 ... +90
solid particle content up to 60%
solid particle maximal size, mm at most 10
Electric motor:
Power, kW 30
Rate speed, rpm 1500
Rated current at 380 W, A 57,6
IP Code IP55

* L – length, W – width, H – height

Operating specifications of pumping stations based on pumps of NC-76R1 series

Pumping station SN-160R1

Parameter name SN-102.30.1,4R1-05.76.15.22
Rated flow, m3/h (lps) at head, wcm. (bar) 102 (28,3) / 30 (3,0)
Max head, wcm (bar) 45 (4,5)
Base pump model NC-76R1
Pressure flange DN, mm 76 (3")
Inlet flange DN, mm 100 (4")
Dimentions, LxBxH, mm 1100х550х1200
Station weight, kg, ±5% 430
Equipment placement category NF
Ambient temperature -45˚С ... +40˚С
Controlled fluid temperature 0˚С ... +80˚С
Pumped fluid properties:
hydraulic fluid density, kg/m3 up to 1400
Temperature, °С +5 ... +90
solid particle content up to 60%
solid particle maximal size, mm at most 10
Electric motor:
Power, kW 22
Rate speed, rpm 1500
Rated current at 380 W, A 42
IP Code IP55

* L – length, W – width, H – height

Operating specifications of pumping stations based on pumps of NC-76R1 series

Pumping station SN-180R1

Parameter name SN-160.32.1,4R1-05.76.15.37
Rated flow, m3/h (lps) at head, wcm. (bar) 160 (44,4) / 32 (3,2)
Max head, wcm (bar) 52 (5,2)
Base pump model NC-76R1
Pressure flange DN, mm 76 (3")
Inlet flange DN, mm 100 (4")
Dimentions, LxBxH, mm 1050х550х1250
Station weight, kg, ±5% 510
Equipment placement category N2
Ambient temperature -10˚С ... +40˚С
Controlled fluid temperature 0˚С ... +80˚С
Pumped fluid properties:
hydraulic fluid density, kg/m3 up to 1400
Temperature, °С +5 ... +90
solid particle content up to 60%
solid particle maximal size, mm at most 10
Electric motor:
Power, kW 37
Rate speed, rpm 1500
Rated current at 380 W, A 58,4
IP Code IP55

* L – length, W – width, H – height